Rated Voltage | Non-inductive Load (A) | Inductive Load (A) | ||||||
Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125VAC | 5 | 1.5 | 0.7 | 3 | 2 | 1 | ||
250VAC | 5 | 1 | 0.5 | 3 | 1.5 | 0.8 | ||
8VDC | 5 | 3 | 5 | 4 | 3 | |||
14VDC | 5 | 3 | 4 | 3 | ||||
30VDC | 5 | 3 | 4 | 3 | ||||
125VDC | 0.4 | - | - | - | ||||
250VDC | 0.2 | - | - | - |
Operating Speed | 0.5mm-50cm/sec |
Operating Frequency | Mechanical: 120 operations/min. |
Electrical: 30 operations/min. | |
Contact Resistance | 25mΩ max. (initial value) |
Insulation Resistance | 100mΩ min. (below 500VDC) |
Dielectric Strength | 1000VAC, 50/60Hz for 1 minute between terminals of the same polarity |
1500VAC, 50/60Hz for 1 minute between current-carrying and non-current metal parts | |
1500VAC, 50/60Hz for 1 minute between each terminal and ground | |
Vibration | 10-55Hz,1.5mm double amplitude |
Shock | Mechanical durable: 1,000m/sec2 (about 100G'S) |
Electrical: 300m/sec2 (about 30G'S) | |
Ambient temperature | -10℃ to 70℃(with no icing) |
Humidity | <95%RH |
Life | Mechanical: 10 Million Operations Above |
Electrical: 500,000 Operations Above | |
Degree of protection | IP65 (IEC Standard) |
MODEL | PLE-101 | PLE-103 | PLE-111 | PLE-121 | PLE-131 |
Operating Force (max.) | 700g | 700g | 700g | 500g | 500g-cm |
Release Force (min.) | 200g | 200g | 200g | 100g-cm | 100g-cm |
Pre Travel (max.) | 1.8mm | 1.8mm | 1.8mm | 200 | 200 |
Trapping Position (min.) | 2.0mm | 2.0mm | 2.0mm | 22.50 | 22.50 |
Movement Diferential (max.) | 1.2mm | 1.2mm | 1.2mm | 100 | 100 |
Total Travel (max.) | 950 | 950 | 950 | 950 | - |
Operating Position (min.) | - | - | - | - | - |
MODEL | DESCRIPTION |
PLE-101 | Plug Column |
PLE-103 | Roller Plug Column |
PLE-111 | One Way Roller Arm Lever (Horizontal) |
PLE-121 | Roller Lever |
PLE-131 | Adjustable Roller Lever |